FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Specified and Substitute Values For the Evaporator Sensor Ihks (A/C Control)





Specified and Substitute Values For the Evaporator Sensor IHKS (A/C Control)

Working range -45°C ... 85°C
Substitute value 0°C
Resistance at 25°C ambient temperature 2849 ohms
Tolerance +/-57 ohms