P0492
27B1 - P0492Informati
on saved
in
DME
Fault
code
27B1 - P0492
Fault text
Secondary air-injection system flow rate, Bank 2
Fault
descriptio
n
Condition
for fault
identifica
tion
Test condition:
Continuous compliance with secondary air-injection system conditions
Terminal condition: Engine running
Voltage condition:
ub > K_DIAG_TR_Plus_Min
Condition
for fault
memory
entry
sls_obdh_mdf_max_intg_norm (after roughly 30 sec.)
k_Sekund�rluftsystem_OBDH_MDF_1_MAG or
sls_obdh_lam_asv_intg_norm >
k_Sekund�rluftsystem_OBDH_Absperrventil_LI_OPE and
K_Sekund�rluftsystem_OBDH_MDF_Min_DEF>K_Sekund�rluftsystem_
OBDH_MDF_Max_DEF
Action in
service
1. Disconnect secondary air-injection line
2. Perform system test
3. If the flow rate is too high replace the shutoff valve
4. Otherwise check line 2 for obstructions and replace as required
Fault
effect and
breakdow
n
warning
MIL is on after 2x engine cold start
Driver
informati
on
Warning light:
No
Service
instructio
n
none