P0156
273B - P0156Information saved in
DME
Fault code
273B - P0156
Fault text
Bank 2 post-catalyst oxygen sensor oscillation check
Fault description
Condition for fault identification
Test condition:
* Engine speed within the boundaries
K_LANK_OBD_S_NMin and K_LANK_OBD_S_NMax *
Engine running since at least the time
K_LANK_OBD_S_TML * Full-load condition for the
minimum time K_LANK_OBD_S_Volllast_T
Terminal condition: Engine running
Voltage condition:
none
Condition for fault memory entry
Oxygen sensor signal too low (low threshold
K_LANK_OBD_S_Volllast_US) for
K_LANK_OBD_S_CNT/K_LANK_OBD_S_AUTOM_CNT
requests
Action in service
1. Check exhaust system for leaks
2. If OK, replace Bank 2 post-catalyst oxygen sensor
Fault effect and breakdown warning
MIL lamp lights up after engine runs 2X
Driver information
Warning light:
No
Service instruction
none