Condition For Fault Memory Entry - Miss In Cycle Sequence
2B4E - P0300Information saved in
DME
Fault code
2B4E - P0300
Fault text
Combustion miss with deterioration of emissions on
multiple cylinders
Fault description
Condition for fault identification
Test condition:
Engine running
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
Combustion miss in cycle sequence on multiple cylinders
Action in service
Note selective logged error codes related to individual
cylinders.
Fault effect and breakdown warning
Rough idle / engine rpm limitation displayed / reduced
power / Check Control message / MIL after engine runs 2x
Driver information
Warning light:
No
Service instruction
none