27A0 - P0606 (DME)
27A0 - P0606Information saved in
DME
Fault code
27A0 - P0606
Fault text
Internal fault within control module
Fault description
Condition for fault identification
Test condition:
none
Terminal condition: none
Voltage condition:
none
Condition for fault memory entry
various internal errors (DSP, reset ...)
Action in service
1. Delete stored DTCs from error memory
2. Replace DME
Fault effect and breakdown warning
Reduced power
Check Control message
Driver information
Warning light:
No
Service instruction
none