(DME) Condition For Fault Memory - at Start of Diagnostics
277A - P1434Information saved in
DME
Fault code
277A - P1434
Fault text
DMTL pump, moisture termination
Fault description
Condition for fault identification
Test condition:
v = 0,
n=0,
pumg >= K_DMTL_P_Min,
K_DMTL_FST_Min <= tank fuel level <= K_DMTL_FST_Max,
K_DMTL_TEMP_Min <= tumg <= K_DMTL_TEMP_Max,
tmot_start >= K_DMTL_TEMP_Start_Min
Terminal condition: Terminal 15 OFF
Voltage condition:
K_DMTL_Plus_Min <= ub <= K_DMTL_Plus_Max
Condition for fault memory entry
Current fluctuation > K_DMTL_I_REF_DIFF during
reference leak measurement at start of diagnostic routine
Action in service
1. Delete stored DTCs from error memory, perform DMTL
system test
2. Check plug and wiring harness on and leading to the
DMTL module
3. Replace DMTL module
Fault effect and breakdown warning
Tank leak diagnosis fails to complete routine, readiness is
not set
Driver information
Warning light:
No
Service instruction
none