Manufacturer Code Charts: 2772
2772 - P0153Information saved in
DME
Fault code
2772 - P0153
Fault text
Bank 2 pre-catalyst oxygen sensor dynamic diagnosis
Fault description
Condition for fault identification
Test condition:
Oxygen load - Forced stimulation with pulse stroke is
active: * Engine temperature > K_O2_OBD_TMOT) *
Engine rom with range (K_O2_OBD_N_Max
u.K_O2_OBD_N_Min)
* Relative induction charge density within range
(K_O2_OBD_Rf_Max u.K_O2_OBD_RF_Min) * Catalytic
converter temperature within range
Terminal condition: Engine running -
idle or partial load
Voltage condition:
none
Condition for fault memory entry
Amplitude of oxygen sensor in minor diagnosis value
K_LAVK_OBD_DYN_WERT_Max
Action in service
1. Delete stored DTCs from error memory, system test on
oxygen sensor
2. Check exhaust system for leaks
3. Replace Bank 2 pre-catalyst oxygen sensor
Fault effect and breakdown warning
MIL on after engine runs 2x / possible mild effect on
drivability...surge during steady-state operation
Driver information
Warning light:
No
Service instruction
none