2764 - P103E (DME)
2764 - P103EInformation saved in
DME
Fault code
2764 - P103E
Fault text
Bank 1 exhaust camshaft VANOS valve
Fault description
Condition for fault identification
Test condition:
none
Terminal condition: Terminal 87 on
Voltage condition:
ub > K_ED_PlusMin
Condition for fault memory entry
Driver diagnosis ATIC35
(overtemperature violation)
Action in service
1. Check valve and replace as indicated
2. Check temperature of DME and E-Box
Fault effect and breakdown warning
Torque reduction / deterioration of emissions quality
Driver information
Warning light:
No
Service instruction
none