P1598
2BAD - P1598Information saved in
DME
Fault code
2BAD - P1598
Fault text
DME2: DME, DME2: hardware, plausibility
Fault description
DME, DME2: Hardware, plausibility
Condition for fault identification
Test condition:
If the control module is in an unlearned or incorrect
condition (injection disabled B_evasga=1), a plausibility
check is run on the value
B_masterhw based on registration of CAN communications
within the control module. If this process recognizes the
encoding in both control modules as correct, the injection is
enabled by resetting B_evasga and the status "learned" is
saved in the block
(B_sggl=1) while the encoding in the non-volatile RAM is
stored in the byte sgaab (learning). If an incorrect condition
is present the injection will only be enabled provided that
the corresponding control module is free of errors.
Terminal condition: Terminal 15=TRUE
Voltage condition:
9.5 < U < 17.9
Condition for fault memory entry
1 sec.
Action in service
Check plug/wiring harness,
check voltage at Pin 3-45,
check voltage at Pin 4-08,
otherwise replace DME
Fault effect and breakdown warning
none
Driver information
Warning light:
none
Service instruction
none