P110F
2BC1 - P110FInformation saved in
DME
Fault code
2BC1 - P110F
Fault text
DME2: Ambient temperature sensor, signal
Fault description
Ambient temperature sensor, signal
Condition for fault identification
Test condition:
I-cluster transmits "invalid" value for ambient temperature
Temp_ex signal error
Terminal condition: Terminal 15=TRUE
Voltage condition:
9V to 16V
Condition for fault memory entry
5 sec.
Action in service
Check plug /wiring harness at instrument cluster, otherwise
replace ambient temperature sensor
Fault effect and breakdown warning
none
Driver information
Warning light:
MIL on in 2nd DC, US version only
Service instruction
none