P0268
2E42 - P0268Information saved in
DME
Fault code
2E42 - P0268
Fault text
DME: HPFI control unit, line 3, activation
Fault description
HPFI control module, line 3, activation
Condition for fault identification
Test condition:
Current on Pin 3-06 > 3.8 A
Terminal condition: nmot > 40 rpm
Voltage condition:
9.5 < U < 17.9
Condition for fault memory entry
none
Action in service
Stecker / check wiring harness, otherwise replace DME
Fault effect and breakdown warning
Miss on two cylinders
Driver information
Warning light:
MIL on in 2nd DC
Service instruction
none