P16C8
2DE0 - P16C8Information saved in
DME
Fault code
2DE0 - P16C8
Fault text
No message from electric fuel pump
Fault description
Serial Communication Link EKP (Electrical Fuel Pump)
Condition for fault identification
Test condition:
EKP recognized
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
none
Action in service
Check CAN link between EKP and DME
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none