FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

P0175

29E1 - P0175

Information saved in
DME

Fault code
29E1 - P0175

Fault text
Mixture control 2

Fault description
System Too Rich (Bank 2)

Condition for fault identification
Test condition:
Closed-loop lambda mixture control = Active
Terminal condition: Engine must be running
Voltage condition:
none

Condition for fault memory entry
75 sec. lambda controller + adaptation deviation in max.
1200 sec.

Action in service
- Visual inspection of affected components
- Reverse mutual installation positions of HFM or injector
valves
- Check HFM plug contacts and electrical wiring
- Check fuel pressure
- Catalyst on one bank melted (visual inspection through O2
sensor fittings)?

Fault effect and breakdown warning


Driver information
Warning light:
MIL on in 2nd driving cycle

Service instruction
none