2DC8
2DC8 - U0101Information saved in
DME
Fault code
2DC8 - U0101
Fault text
No message from EGS, EGS 1
Fault description
Lost Communication With TCM
Condition for fault identification
Test condition:
EGS detected
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
5 sec.
Action in service
Check CAN link to EGS control module
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none