(DME) Condition For Fault ID - Checksum Error
CDBE - U1148Information saved in
DME
Fault code
CDBE - U1148
Fault text
Bank 2 idle actuator CAN message
Fault description
Condition for fault identification
Test condition:
none
Terminal condition: Terminal 87
Voltage condition:
ub > K_EGAS_CAN_ED_Plus_Min
Condition for fault memory entry
Checksum error > K_CAN_CHKurzschlussUM_ERR_Max
Action in service
1. Delete stored DTCs from error memory, idle actuator
system test
2. Program DME
3. Replace DME
Fault effect and breakdown warning
DSC lamp / CC message / engine speed limited to 5000 rpm
/ reduced power / engine start may be possible only with use
of accelerator pedal
Driver information
Warning light:
29-Engine malfunction
Service instruction
none