P2432
2739 - P2432Information saved in
DME
Fault code
2739 - P2432
Fault text
Electrical diagnosis of secondary-air injection mini-HFM
Fault description
Condition for fault identification
Test condition:
Terminal condition: Engine running
Condition for fault memory entry
Air mass < K_SL_ML_HFM_DIAG_Min
Action in service
1. Check plug and wiring harness on Mini-HFM
2. Replace Mini-HFM
Fault effect and breakdown warning
MIL lamp lights up after two driving cycles
Driver information
Warning light:
Yes
Service instruction
none