P010C
2713 - P010CInformation saved in
DME
Fault code
2713 - P010C
Fault text
Bank 2 mass airflow sensor
Fault description
Condition for fault identification
Test condition:
No
Terminal condition: No
Voltage condition:
No
Condition for fault memory entry
Measured value < K_HFM_DIAG_ML_Min
Action in service
1. Check plug and wiring harness at Bank 2 HFM,
2. replace Bank 2 HFM
Fault effect and breakdown warning
Error display in instrument / power reduction / engine speed
governed to 7000 rpm / MIL on after engine runs 2x
Driver information
Warning light:
29-Engine malfunction
Service instruction
none