2B24 - P159C (DME)
2B24 - P159CInformation saved in
DME
Fault code
2B24 - P159C
Fault text
Idle actuator governor monitoring, Bank 2
Fault description
Condition for fault identification
Test condition:
Communications and CAN OK
Terminal condition: Terminal 87
Voltage condition:
ub > K_EGAS_CAN_ED_Plus_Min
Condition for fault memory entry
Adaptation error
Action in service
1. Delete stored DTCs from error memory, conduct idle
actuator system test
2. Check plug and wiring harness at/to idle actuator 2
3. Replace idle actuator 2
Fault effect and breakdown warning
Engine speed limited to 5000 rpm / Check Control message /
DSC lamp / power reduction
Driver information
Warning light:
29-Engine malfunction
Service instruction
none