275F - P0011 (DME)
275F - P0011Information saved in
DME
Fault code
275F - P0011
Fault text
VANOS maximum limit position, intake Bank 1
Fault description
Condition for fault identification
Test condition:
Pressure detected, no current quality measurement, specified
and actual variation > as van_ist_anschl -
K_VAN_ANSCHL_DELTA
Terminal condition: Engine running
Voltage condition:
none
Condition for fault memory entry
Variation at limit > (K_VAN_SPR_Max+
K_VAN_SPR_Max_TOL)
Action in service
1. Delete stored DTCs from error memory, VANOS system
test
2. Check VANOS valves
3. Check camshaft adjustment
Fault effect and breakdown warning
Reduced power
Driver information
Warning light:
No
Service instruction
none