U112B
2DCF - U112BInformation saved in
DME
Fault code
2DCF - U112B
Fault text
No message from instrument panel, DME receiver,
instrument panel transmitter
Fault description
CAN instrument cluster: Signal error
Condition for fault identification
Test condition:
B_siins_fr = TRUE (MIN ERROR, alive signal not OK).
Terminal condition: 800 ms after Terminal 15
Voltage condition:
battery voltage >10 V
Condition for fault memory entry
700 ms
Action in service
- Measure resistance on bus
- Check instrument cluster ECU
- Check ZGM
- Check K-CAN
- Check wiring harness
=> Replace ECU as indicated
Fault effect and breakdown warning
none
Driver information
Warning light:
MIL on in 2nd DC, US version only
Service instruction
none