P3252
2A19 - P3252Information saved in
DME
Fault code
2A19 - P3252
Fault text
DME2: Tank-venting valve, activation
Fault description
Tank EVAP valve, activation
Condition for fault identification
Test condition:
Current at Pin 3-21 I > 3.8 A
Terminal condition: Terminal 15
Voltage condition:
9.5 < U < 17.9
Condition for fault memory entry
n> 40 rpm, 2% <= tateist_w <= 80%
Action in service
Stecker / check wiring harness, otherwise replace DME
Fault effect and breakdown warning
none
Driver information
Warning light:
MIL ON in 2nd DC
Service instruction
none