P322F
2F77 - P322FInformation saved in
DME
Fault code
2F77 - P322F
Fault text
DME2: Ambient-pressure sensor, plausibility
Fault description
Barometric pressure sensor, plausibility
Condition for fault identification
Test condition:
Ambient barometric pressure < 560hPa
Terminal condition: Terminal 15
Voltage condition:
9V to 16V
Condition for fault memory entry
2 sec.
Action in service
Replace DME
Fault effect and breakdown warning
none
Driver information
Warning light:
MIL on in 2nd DC, US version only
Service instruction
none