P322C
2F78 - P322CInformation saved in
DME
Fault code
2F78 - P322C
Fault text
DME2: DME, internal fault: ambient-pressure sensor
Fault description
DME, internal malfunction: Ambient barometric pressure
sensor
Condition for fault identification
Test condition:
Internal voltage measurement in ambient pressure sensor U
> 4.8047
Terminal condition: Terminal 15
Voltage condition:
9V to 16V
Condition for fault memory entry
1 sec.
Action in service
Replace DME
Fault effect and breakdown warning
none
Driver information
Warning light:
MIL on in 2nd DC, US version only
Service instruction