P3208
2DD9 - P3208Information saved in
DME
Fault code
2DD9 - P3208
Fault text
DME2: No message from ARS
Fault description
CAN, ARS: Signal error
Condition for fault identification
Test condition:
Plausibility check on torque demand from ARS with model
figures calculated from lateral acceleration and speed
Terminal condition: 800 ms after Terminal 15
Voltage condition:
battery voltage >10 V
Condition for fault memory entry
500 ms
Action in service
- Check DSC + ARS
- Measure resistance on bus
- Check wiring harness
=> Replace affected ECU as indicated
Fault effect and breakdown warning
none
Driver information
Warning light:
none
Service instruction
none