P3029
2CA0 - P3029Information saved in
DME
Fault code
2CA0 - P3029
Fault text
DME2: Oxygen-sensor heating before catalytic converter,
bank 2
Fault description
Pre-catalyst oxygen sensor heater
Condition for fault identification
Test condition:
Error path not active
Terminal condition: none
Voltage condition:
none
Condition for fault memory entry
none
Action in service
Check plug, replace sensor
Fault effect and breakdown warning
none
Driver information
Warning light:
none
Service instruction
none