FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

P3019

2C4D - P3019

Information saved in
DME

Fault code
2C4D - P3019

Fault text
DME2: Oxygen sensor before catalytic converter, bank 2,
pump current line

Fault description
Pre-catalyst oxygen sensor, pump current cable

Condition for fault identification
Test condition:
Monitoring on disconnected pump current wire (IP);
Diagnosis conditions:
- Closed-loop lambda control active and control deviation >
10 %
- Voltage at CJ125 at 1.5 V (1.49?.1.51V)
- Forced amplitude active
Terminal condition: Engine operation, part load
Voltage condition:
battery voltage<11V oder Ubatt > 16 volts

Condition for fault memory entry
Fault monitoring criterion must remain present over 3 sec.

Action in service
Check plugs/wiring harness, otherwise replace sensor

Fault effect and breakdown warning
none

Driver information
Warning light:
MIL on in 2nd DC

Service instruction
none