P1676
2DBF - P1676Information saved in
DME
Fault code
2DBF - P1676
Fault text
No message, receiver DME, transmitter ACC
Fault description
CAN, ACC: Signal error
Condition for fault identification
Test condition:
B_npacc_um = TRUE or B_npac2_um = TRUE is (PLAUS
ERROR, checksum error).
Terminal condition: 800 ms after Terminal 15
Voltage condition:
battery voltage >10 V
Condition for fault memory entry
200 ms
Action in service
- Check other ECUs for CAN fault
- Measure resistance on bus
- Check wiring harness Replace defective ECU as indicated
Fault effect and breakdown warning
none
Driver information
Warning light:
none
Service instruction
none