P1666
2F44 - P1666Information saved in
DME
Fault code
2F44 - P1666
Fault text
DME2: EWS preventing manipulation
Fault description
Immobilizer anti-tampering protection
Condition for fault identification
Test condition:
Starting at T15 ON
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
An incorrect start value telegram
Action in service
If the DME really is correct for this vehicle, switch Terminal
15 off/on, repeat start data calibration; if not OK, replace
CAS; => Status feedback after start value calibration has
priority over FS
Fault effect and breakdown warning
Starter turns, engine fails to start
Driver information
Warning light:
none
Service instruction
none