P1596
2DE6 - P1596Information saved in
DME
Fault code
2DE6 - P1596
Fault text
DME2: Local CAN, DME/DME2: communication
Fault description
Local CAN, DME/DME2: Communications
Condition for fault identification
Test condition:
determine whether the following message
DME_M_S_1,DME_M_S_2,DME_M_S_T1 is present
Terminal condition: 800 ms after Terminal 15
Voltage condition:
battery voltage >10 V
Condition for fault memory entry
500 ms
Action in service
if 2 errors are present (bus off / CAN timeout)
=> Check local CAN
Check power supply
=> Replace interacting control module as indicated
Fault effect and breakdown warning
If master is affected vehicle will fail to start
Driver information
Warning light:
MIL on in 2nd DC
Service instruction
none