Courtesy of Operation CHARM: Car repair manuals for everyone.

P1026

2A61 - P1026

Information saved in
DME

Fault code
2A61 - P1026

Fault text
DME2: Valvetronic bank 2, adjustment range

Fault description
Valvetronic, adjustment range

Condition for fault identification
Test condition:
- Fault class:
Adjustment range faulty
Terminal condition: Terminal 15 ON
Voltage condition:
>= 9 V

Condition for fault memory entry
none

Action in service
Check balance spring installation; check mechanical
components for wear and stiction

Fault effect and breakdown warning
- VVT in emergency default mode
- Customer perception depends upon the system's ability to
achieve maximum-stroke position. If the
excentric shaft can reach the maximum-stroke position
the vehicle will not display any perceptible
performance changes (only higher fuel consumption).
-

Driver information
Warning light:
none

Service instruction
none