P0562
2F8A - P0562Information saved in
DME
Fault code
2F8A - P0562
Fault text
DME2: Battery voltage
Fault description
Battery voltage
Condition for fault identification
Test condition:
Voltage measurement at Pin 1-08 U < 2.54
Terminal condition: TR 15
Voltage condition:
none
Condition for fault memory entry
25 sec.
Action in service
Check wiring harness
Replace ECU as indicated
Fault effect and breakdown warning
none
Driver information
Warning light:
MIL on in 2nd DC, US version only
Service instruction
none