P0205
2E41 - P0205Information saved in
DME
Fault code
2E41 - P0205
Fault text
DME: HPFI control unit, line 5, activation
Fault description
HPFI control module, line 5, activation
Condition for fault identification
Test condition:
Voltage at Pin 3-07 < 2.1V
Terminal condition: nmot > 40 rpm
Voltage condition:
9.5 < U < 17.9
Condition for fault memory entry
none
Action in service
Stecker / check wiring harness, otherwise replace DME
Fault effect and breakdown warning
Miss on two cylinders
Driver information
Warning light:
MIL on in 2nd DC
Service instruction
none