2F8A - P0561 (DME)
2F8A - P0561Information saved in
DME
Fault code
2F8A - P0561
Fault text
DME2: Battery voltage
Fault description
Battery voltage
Condition for fault identification
Test condition:
Voltage measurement at Pin 1-08 detects substantial voltage
fluctuation U<8.01 and U> 16.48
Terminal condition: Terminal 15 and V > 10 km/h at mx
threshold active
Voltage condition:
none
Condition for fault memory entry
N
Action in service
Check terminals,
replace battery as indicated
Fault effect and breakdown warning
none
Driver information
Warning light:
MIL on in 2nd DC, US version only
Service instruction
none