2F77 - P323B (DME)
2F77 - P323BInformation saved in
DME
Fault code
2F77 - P323B
Fault text
DME2: Ambient-pressure sensor, plausibility
Fault description
Barometric pressure sensor, plausibility
Condition for fault identification
Test condition:
The difference in ambient barometric pressure between the
master and slave ECUs varies by +/- 60 hPa
Terminal condition: Terminal 15
Voltage condition:
9V to 16V
Condition for fault memory entry
2 sec.
Action in service
Read out the ambient barometric pressure from each control
module and compare to the current atmospheric pressure,
replace the control module providing the incorrect readings
Fault effect and breakdown warning
none
Driver information
Warning light:
MIL on in 2nd DC, US version only
Service instruction
none