2E72 - P1381 (DME)
2E72 - P1381Information saved in
DME
Fault code
2E72 - P1381
Fault text
DME2: Control unit, bank 2, internal fault: knock-sensor
module
Fault description
Control module, internal fault: Knock sensor chip
Condition for fault identification
Test condition:
Parity error
Terminal condition: Engine running
Voltage condition:
9 - 15 V
Condition for fault memory entry
< 10 sec.
Action in service
Replace DME
Fault effect and breakdown warning
Minimal power loss (with operation on RON 91 fuel, etc.)
Driver information
Warning light:
MIL on
Service instruction
none