2D6E
2D6E - P1603Information saved in
DME
Fault code
2D6E - P1603
Fault text
DME2: DME, internal fault, bank 2: monitoring, actual
torque
Fault description
Internal malfunction in DME: Actual torque monitor
Condition for fault identification
Test condition:
Error from torque comparison that can also stem from a
load-signal error
Terminal condition: Terminal 15
Voltage condition:
9V to 16V
Condition for fault memory entry
none
Action in service
Check HFM for contamination, if OK => Replace DME
Fault effect and breakdown warning
none
Driver information
Warning light:
EPCL
Service instruction