2D1C - P2127 (DME)
2D1C - P2127Information saved in
DME
Fault code
2D1C - P2127
Fault text
DME2: Accelerator pedal module, pedal-travel sensor,
signal 2
Fault description
Accelerator pedal module, pedal-travel sensor, signal 2
Condition for fault identification
Test condition:
Voltage at pot 1 Pin 4-13
U< 0.566V
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
140 ms
Action in service
Check plug/wiring harness, otherwise pedal-travel sensor
module, then replace DME
Fault effect and breakdown warning
In pedal-travel sensor default operation upwg is set to the
lowest possible lower normalization limit UPWGUR 0.8V
Driver information
Warning light:
none
Service instruction
none