2CA8 - P0141 (DME)
2CA8 - P0141Information saved in
DME
Fault code
2CA8 - P0141
Fault text
DME2: Oxygen-sensor heating after catalytic converter,
bank 2, function
Fault description
Pre-catalyst oxygen sensor heater operation
Condition for fault identification
Test condition:
Oxygen sensor behind cat. heater on
Exhaust-gas temperature at sensor (model)
Dew point end reached 140 sec. after heater assumes
operation
Terminal condition: Terminal 15 on
Engine running
Voltage condition:
Battery voltage
11V < battery voltage < 16V
Condition for fault memory entry
Time
26 sec./continuous
Action in service
Replace LSH
Fault effect and breakdown warning
none
Driver information
Warning light:
MIL on in 2nd DC
Service instruction
none