2C4D - P3018 (DME)
2C4D - P3018Information saved in
DME
Fault code
2C4D - P3018
Fault text
DME2: Oxygen sensor before catalytic converter, bank 2,
pump current line
Fault description
Pre-catalyst oxygen sensor, pump current cable
Condition for fault identification
Test condition:
Monitoring on disconnected pump current wire (IP);
Diagnosis conditions:
- Closed-loop lambda control active and control deviation >
10 %
- Voltage at CJ125 at 1.5 V (1.49?.1.51V)
- Forced amplitude active
Terminal condition: Engine operation, part load
Voltage condition:
battery voltage<11V oder Ubatt > 16 volts
Condition for fault memory entry
Fault monitoring criterion must remain present over 3 sec.
Action in service
Check plugs/wiring harness, otherwise replace sensor
Fault effect and breakdown warning
none
Driver information
Warning light:
MIL on in 2nd DC
Service instruction
none