2C4B - P3012 (DME)
2C4B - P3012Information saved in
DME
Fault code
2C4B - P3012
Fault text
DME2: Control unit, internal fault, bank 2: oxygen-sensor
module
Fault description
Control module, internal fault: Oxygen sensor module
Condition for fault identification
Test condition:
Monitor for voltage adaptation value electr. calibration of
CJ125 IC
Calibration runs after engine start and in idle phases
Terminal condition: Terminal 15 ON
Voltage condition:
battery voltage<11V oder Ubatt > 16 volts
Condition for fault memory entry
Fault criterion:
Calibration adaptation value > 0.1 volts
Fault entry after 10 sec.
Action in service
Check plug, replace sensor
Fault effect and breakdown warning
none
Driver information
Warning light:
MIL on in 2nd DC
Service instruction
none