2C24
2C24 - P0040Information saved in
DME
Fault code
2C24 - P0040
Fault text
DME2: Oxygen sensors before catalytic converter, bank 2,
mixed up
Fault description
Pre-catalyst oxygen sensor connection positions transposed
Condition for fault identification
none
Condition for fault memory entry
none
Action in service
Correctly connect pre-catalyst oxygen sensors, check wiring
harness as indicated to determine whether the oxygen-sensor
inputs on the modular plug at the DME are assigned
correctly; -; check HPFI wiring
Fault effect and breakdown warning
Driver information
none
Service instruction
none