2BAC
2BAC - P1564Information saved in
DME
Fault code
2BAC - P1564
Fault text
DME2: DME, DME2: program-status difference
Fault description
DME, DME2: Program version difference
Condition for fault identification
Test condition:
Prior to engine start the slave data ID is linked to the master
via the LOcan.
The master compares its own ID with the ID of the slave and
couples an "OK" or "not OK" back. A DTC is then entered
in one of the two control modules.
Terminal condition: none
Voltage condition:
none
Condition for fault memory entry
none
Action in service
- Program the same program version in master and slave
- Following successful in-vehicle reprogramming the error
should no longer be active
Fault effect and breakdown warning
Depending upon the differences in the program versions
Driver information
Warning light:
none
Service instruction