2B84 - P0660 (DME)
2B84 - P0660Information saved in
DME
Fault code
2B84 - P0660
Fault text
DME: Auxiliary air flap, activation
Fault description
Auxiliary air flap, activation
Condition for fault identification
Test condition:
Voltage at Pin 3-22 4.4 V < UBatt < 5.6V
Terminal condition: Terminal 15
Voltage condition:
9.5 < U < 17.9
Condition for fault memory entry
n> 40 rpm
Action in service
Stecker / check wiring harness, otherwise replace DME
Fault effect and breakdown warning
none
Driver information
Warning light:
none
Service instruction
none