2B7A - P0005 (DME)
2B7A - P0005Information saved in
DME
Fault code
2B7A - P0005
Fault text
DME: Return-flow shut-off valve, activation
Fault description
Activation of return shut-off valve
Condition for fault identification
Test condition:
Voltage at Pin 1-02 4.4 V < UBatt < 5.6V
Terminal condition: Terminal 15
Voltage condition:
9.5 < U < 17.9
Condition for fault memory entry
n> 40 rpm
Action in service
Stecker / check wiring harness, otherwise replace DME
Fault effect and breakdown warning
none
Driver information
Warning light:
none
Service instruction
none