2A6D - P1081 (DME)
2A6D - P1081Information saved in
DME
Fault code
2A6D - P1081
Fault text
DME2: Valvetronic bank 2, electric overload protection
Fault description
Valvetronic, electrical overload protection
Condition for fault identification
Test condition:
- Fault class:
E motor temperature too high
Terminal condition: Terminal 15 ON
Voltage condition:
none
Condition for fault memory entry
45 ms
Action in service
Checking resistance between winding and casing is not
possible with available test technology; check magnets in
reluctor to determine if they have fallen out;
check reluctor installation;
check for wear and stiction in mechanical components
Fault effect and breakdown warning
VVT - Emergency default mode (VVT driver circuit
deactivation)
Driver information
Warning light:
none
Service instruction
none