2A6C - P1099 (DME)
2A6C - P1099Information saved in
DME
Fault code
2A6C - P1099
Fault text
DME2: Valvetronic bank 2, position at new start:
plausibility
Fault description
Valvetronic, position at restart: Plausibility
Condition for fault identification
Test condition:
- Fault class:
VVT data comparison
Deactivation position / Start position
(plausibility fault)
Terminal condition: Terminal 15 ON
Voltage condition:
none
Condition for fault memory entry
500 ms
Action in service
Terminal 15 off, wait until HR releases, Terminal 15 on,
VVT initializes automatically
Fault effect and breakdown warning
VVT - Emergency default mode (max. stroke) higher fuel
consumption
Driver information
Warning light:
none
Service instruction