FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

2A5F - P1019 (DME)

2A5F - P1019

Information saved in
DME

Fault code
2A5F - P1019

Fault text
DME2: Valvetronic bank 2, eccentric-shaft sensor: power
supply

Fault description
Valvetronic, excentric shaft sensor: Voltage supply

Condition for fault identification
Test condition:
- Fault class:
Voltage too high on sensor
power supply
Terminal condition: DME, VVT - Active
Voltage condition:
4.5 V - 5.5 V

Condition for fault memory entry
3 ms

Action in service
Check plug and wiring harness, with short to +12V there is
danger of a sensor defect; check VVT-SG output voltage
(max. 5.5 V)

Fault effect and breakdown warning
VVT - Emergency default mode (max. stroke) higher fuel
consumption

Driver information
Warning light:
none

Service instruction
none