P323C
2F77 - P323CInformation saved in
DME
Fault code
2F77 - P323C
Fault text
Ambient-pressure sensor, plausibility
Fault description
Ambient Pressure Sensor Comparison Current to Last
Driving Cycle Implausible
Condition for fault identification
Test condition:
Ambient pressure > 1150 hPa
Terminal condition: Terminal 15=TRUE
Voltage condition:
9 V < U > 16 V
Condition for fault memory entry
5 sec.
Action in service
Replace DME
Fault effect and breakdown warning
Driver information
Warning light:
MIL on in 2nd DC, US version only
Service instruction
none