P3219
2DDC - P3219Information saved in
DME
Fault code
2DDC - P3219
Fault text
No message from SZL
Fault description
CAN Message Monitoring SZL (Switch Cluster Steering
Column) Alive Check
Condition for fault identification
Test condition:
No suspension of bus activity
Terminal condition: 800 ms after Terminal 15
Voltage condition:
battery voltage >10 V
Condition for fault memory entry
400 ms
Action in service
- Check other ECUs for CAN fault
- Measure resistance on bus
- Check wiring harness Replace defective ECU as indicated
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none