P3014
2C4B - P3014Information saved in
DME
Fault code
2C4B - P3014
Fault text
Control module, internal fault: oxygen sensor module
Fault description
O2 Sensor WRAF-IC Supply Voltage Too Low (Bank 1
Sensor 1)
Condition for fault identification
Test condition:
Monitor for CJ125 chip power supply; voltage too low
Terminal condition: Terminal 15 ON
Voltage condition:
battery voltage<11V oder Ubatt > 16 volts
Condition for fault memory entry
Fault monitoring criterion must remain present over 2 sec.
Action in service
Replace control module
Fault effect and breakdown warning
Driver information
Warning light:
MIL on (in 2nd driving cycle);
Service instruction
none